Title 24 Compliance

Slide background

MEET TITLE 24

HVAC & LIGHTING COMPLIANCE

Reduce energy use, lower operating costs and meet code requirements.

Slide background
Slide background

Meet Title 24 Compliance with Energy Efficient Lighting and HVAC Controls

California’s Title 24 – the California Building Standards Code – ensures that all new buildings and those undergoing substantial renovations throughout the state adhere to strict guidelines to achieve energy efficiency and preserve both outdoor and indoor environmental quality. The simplest and easiest way to reduce lighting in buildings is to automatically turn off lights and manage HVAC temperatures when rooms are not occupied. There are key provisions within Title 24 that require hotel operators to more effectively manage energy use by:

  • Automatically shutting off guest room lighting within 30 minutes of the room being vacated
  • Requiring that at least one-half of all receptacles are controlled, and are automatically shut off within 30 minutes of the room being vacated
  • Automatically raising temperatures by +/- 5°F (+/- 3°C) in cooling mode and lowering temperatures by +/- 5°F (+/- 3°C) in heating mode within 30 minutes of the room being vacated
  • Installing thermostats with numeric setpoints, with established setpoint stops which are accessible only to authorized personnel
  • Limiting the ability of guests to adjust the setpoint by more than +/- 5°F (+/- 3°C) above or below the established setpoint stop in heating or cooling mode

Our Title 24 Solution

The Evolve Connected Room Solution is ideally positioned to comply with California Title 24 through our suite of thermostats, lighting controls, receptacles, door contacts and card key systems. Our lighting, shading and HVAC control products are designed to meet today’s rigorous energy codes and standards.

Lighting Control

faceplates

Evolve switches and dimmers provide the flexibility to design the optimal in-room lighting system to engage today’s eco-conscious customer.

Smart Thermostats

battery-thermostat

Our line of thermostats and temperature sensors are designed to control the majority of HVAC systems and are Title 24 compliant.

Occupancy Sensors

The thermostat and lighting occupancy setback is used with the motion sensor, door sensor, or keycard reader to reduce wasted energy.

Outlets & Plug-Ins

outlets-plugin-modules

Install our smart outlet, or convert a standard outlet to a smart outlet via an our plug-in module to ensure guest device control.

Sample Floor Plan

The following sample floor plan illustrates where our full line of Title-24 compliant devices are typically installed.

1
2
3
4
5
6
7
8
9
10
1

DOOR CONTACT

DS100 Door Sensor
Battery powered with extremely small form factor and aesthetic design, the Evolve door sensor will send RF signals to associated Evolve devices within its own RF network when the main unit separates from the smaller unit.

INSTALLATION: Recesses at entry door. No wiring necessary.

2

SECTION 130.1: INDOOR LIGHTING CONTROLS

LSM Binary Switch

130.1.C.8 Hotel/motel guestrooms shall have captive key card control, occupancy sensing controls, or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, lighting power is turned off.

SOLUTION: Evolve’s RF Wireless Lighting Controls:
• Binary Switch (On/Off)
• Dimmer Switch
• Accessory / 3-Way Switch

Occupancy-Based Setback:
1. Keycard; or
2. Heat / Motion Sensor + Door Contact

3

SECTION 120.2: THERMOSTAT

thermostat

120.2.E.4 Hotel/motel guestrooms shall have captive key card controls, occupancy sensing controls, or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, setpoints are setup at least +/- 5F (+/- 3C) in cooling mode and set down at least +/- 5F (+/- 3C) in heating mode.

SOLUTION: Evolve offers devices commissioned with logic that allows for:
A. Occupancy-based Setback
1. Keycard; or
2. Heat/Motion Sensor + Door Contact
B. Maximum and minimum setpoint configuration

INSTALLATION: 120v and 24v solutions available. Programmed for setback based on state of occupancy controls.

4

SECTION 130.5: CIRCUIT CONTROL FOR 120V RECEPTACLES

LOM Receptacle

130.5.D For hotel and motel guestrooms at least 1/2 of the 120v receptacles in each guestroom shall be controlled receptacles that comply with section 130.5.D 1, 2, and 3.
Electric circuits serving controlled receptacles shall have captive key card controls, occupancy sensing controls or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, power is switched off.

SOLUTION: Evolve’s RF Duplex Receptacles offer wireless 1/2 controlled outlets:
1. Keycard; or
2. Heat/Motion Sensor + Door Contact

INSTALLATION: 120v to be present.

5

OCCUPANCY SENSOR

PIR 200 Occupancy Sensor

INSTALLATION: Battery-Operated Device; mechanically fastens to ceiling or wall. No wiring necessary.

6

SECTION 130.5: CIRCUIT CONTROL FOR 120V RECEPTACLES

LOM Receptacle

130.5.D For hotel and motel guestrooms at least 1/2 of the 120v receptacles in each guestroom shall be controlled receptacles that comply with section 130.5.D 1, 2, and 3.
Electric circuits serving controlled receptacles shall have captive key card controls, occupancy sensing controls or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, power is switched off.

SOLUTION: Evolve’s RF Duplex Receptacles offer wireless 1/2 controlled outlets:
1. Keycard; or
2. Heat/Motion Sensor + Door Contact

INSTALLATION: 120v to be present.

7

SECTION 130.5: CIRCUIT CONTROL FOR 120V RECEPTACLES

LOM Receptacle

130.5.D For hotel and motel guestrooms at least 1/2 of the 120v receptacles in each guestroom shall be controlled receptacles that comply with section 130.5.D 1, 2, and 3.
Electric circuits serving controlled receptacles shall have captive key card controls, occupancy sensing controls or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, power is switched off.

SOLUTION: Evolve’s RF Duplex Receptacles offer wireless 1/2 controlled outlets:
1. Keycard; or
2. Heat/Motion Sensor + Door Contact

INSTALLATION: 120v to be present.

8

SECTION 130.5: CIRCUIT CONTROL FOR 120V RECEPTACLES

LOM Receptacle

130.5.D For hotel and motel guestrooms at least 1/2 of the 120v receptacles in each guestroom shall be controlled receptacles that comply with section 130.5.D 1, 2, and 3.
Electric circuits serving controlled receptacles shall have captive key card controls, occupancy sensing controls or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, power is switched off.

SOLUTION: Evolve’s RF Duplex Receptacles offer wireless 1/2 controlled outlets:
1. Keycard; or
2. Heat/Motion Sensor + Door Contact

INSTALLATION: 120v to be present.

9

SECTION 130.5: CIRCUIT CONTROL FOR 120V RECEPTACLES

LOM Receptacle

130.5.D For hotel and motel guestrooms at least 1/2 of the 120v receptacles in each guestroom shall be controlled receptacles that comply with section 130.5.D 1, 2, and 3.
Electric circuits serving controlled receptacles shall have captive key card controls, occupancy sensing controls or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, power is switched off.

SOLUTION: Evolve’s RF Duplex Receptacles offer wireless 1/2 controlled outlets:
1. Keycard; or
2. Heat/Motion Sensor + Door Contact

INSTALLATION: 120v to be present.

10

SECTION 130.1: INDOOR LIGHTING CONTROLS

LSM Binary Switch

130.1.C.8 Hotel/motel guestrooms shall have captive key card control, occupancy sensing controls, or automatic controls such that, no longer than 30 minutes after the guestroom has been vacated, lighting power is turned off.

SOLUTION: Evolve’s RF Wireless Lighting Controls:
• Binary Switch (On/Off)
• Dimmer Switch
• Accessory / 3-Way Switch

Occupancy-Based Setback:
1. Keycard; or
2. Heat / Motion Sensor + Door Contact

Construction Documents

The following documentation consists of Construction Specifications Institute’s Section 25.51.13 – Integrated Room Automation & Property Services Systems, Products and Execution.

Evolve Controls helps customers meet today’s energy codes and standards, access rebate and incentive funding, and earn industry recognition for superior energy and sustainability performance.

For a consultation to discuss how Evolve can help you meet Title 24 compliance for a new construction or renovation, contact: